Honeywell CC-TAID01 Analog Input Module
- Product Code: CC-TAID01
- Availability: In Stock
Purchase Attributes:Original, Brand New
Service Attributes
▷ Stock & Logistics:Fast Delivery
▷ After-sales Guarantee:12 Months Warranty
▷ Online Customer Service:24 Hours Online Support
▷ Product Advantages:Competitive Price, Long Service Life
Application Attributes:Honeywell CC-TAID01 Analog Input Module
Honeywell CC-TAID01 16-Channel Isolated 4-20mA HART Analog Input Module (For Experion PKS C300 / C200 Controller)
Manufacturer: Honeywell Process Solutions
Model: CC-TAID01 (C Series I/O Card for Experion PKS DCS)
Matching Controller: C300 / C200 Process Controller via FTE I/O Carrier Rack; Not compatible with TDC300, FSC SIS systems
Type: Hot-swappable 16-channel galvanic isolated analog input module, native HART 5/7 digital communication support
Core Function: High-precision acquisition of 4–20mA 2-wire loop-powered transmitter signals (flow, pressure, level, temperature); per-channel open/short circuit detection, overvoltage surge protection, redundant FTE communication, predictive maintenance via HART device diagnostics; used for continuous process closed-loop control in refinery, power plant, chemical plant
1. Product Overview
CC-TAID01 is the mainstream analog input card of Honeywell C Series I/O platform, exclusively designed for Experion PKS distributed control system. It adopts single-channel independent isolation design to eliminate ground loop interference caused by field equipment potential difference, solving unstable measurement problems in high-frequency inverter, motor cabinet environments.
It supports full HART protocol, can read instrument internal parameters, calibration data, alarm status and device self-diagnosis information without additional HART adapter, realizing predictive maintenance of field transmitters. Each channel provides built-in loop power supply for 2-wire transmitters, no external 24VDC field power required.
Hot-plugging design allows online replacement without shutting down the controller rack; built-in multi-level hardware watchdog, channel-by-channel fault self-test, fault signal uploaded to Experion station for alarm display. The module communicates with C300 controller through redundant FTE fault-tolerant Ethernet I/O carrier, supporting dual redundant I/O rack configuration to improve system availability.
Matched with dedicated analog FTA terminal base for field wiring separation, widely deployed in ethylene cracking, refining unit, thermal power boiler & turbine main process measurement cabinets.
2. Complete Technical Specifications
• Channel Count: 16 fully independent analog input channels
• Input Signal Standard: 4–20mA DC loop-powered two-wire transmitter; 0–20mA extended range supported
• Galvanic Isolation: 1500VAC rms per channel isolation between field circuit and control logic
• HART Compatibility: HART 5 / HART 7 multi-drop digital communication per channel
• Measurement Accuracy: ±0.075% full scale typical, ±0.15% full scale maximum
• Resolution: 16-bit high precision A/D conversion
• Loop Supply: 22–26VDC built-in loop power for each channel, max 22mA drive capability
• Channel Diagnostics: Open circuit, short circuit, over-range, under-range, loop fault detection per channel
• Surge & ESD Protection: ±15kV contact ESD, 2kV line surge suppression on all field terminals
• Hot Swap Support: Hot plug/unplug without controller rack power off
• Communication Bus: Redundant FTE fault-tolerant Ethernet to C300 controller
• Operating Temperature: 0℃ ~ +60℃ forced air cabinet environment
• Storage Temperature: -40℃ ~ +85℃
• Humidity: 5% ~ 95% RH non-condensing
• Power Consumption: Max 18W total module power from rack backplane 24VDC
• Mechanical Size: Standard C Series I/O module card, rack slot mounted, single slot occupancy
• Certification: CE, UL508, CSA industrial safety certification
3. Core Hardware Features
1. Per-channel independent isolation transformer, eliminate cross-channel interference and ground loop drift
2. Native HART modulation/demodulation circuit, no external HART interface card required
3. 16-bit high linearity A/D converter, stable measurement under low signal fluctuation
4. Multi-color front panel LED: RUN, FAULT, COMM, channel status indicator
5. Dual redundant FTE communication interface, automatic switchover when single network fails
6. Complete channel self-diagnosis, fault timestamp recording and event upload to Experion server
4. Industrial Application Scenarios
• Petrochemical refinery & ethylene plant: flow, pressure, level, temperature transmitter signal acquisition for main distillation, cracking reactor control loops
• Thermal power plant boiler & turbine DCS rack: steam pressure, feedwater flow, furnace temperature continuous analog measurement
• Offshore oil & gas platform process control cabinet: HART intelligent transmitter multi-channel signal collection
• Chemical plant reactor continuous process monitoring, closed-loop PID control analog input front-end
Honeywell © CC-TAID01 C Series HART Analog Input Module for Experion PKS C300